From cconnor@CoorsTek.com Mon Sep 26 16:11:43 2016 Date: Mon, 26 Sep 2016 21:11:35 +0000 From: "Connor, Cheryl R" To: "frisch@hep.uchicago.edu" Subject: RE: Request for Information [ The following text is in the "utf-8" character set. ] [ Your display is set for the "ISO-8859-1" character set. ] [ Some characters may be displayed incorrectly. ] Hi Henry,   Unfortunately, we do not have any data available for frequency at 1 GHz but we do have data at 3 GHz:   Dielectric Constant = 9.2 Tan delta = 7.5X10-4   Regards, Cheryl Connor Customer Engagement Center Lead cid:4FC8100E-53BC-416F-A3D3-8E0BF07A455E Phone: +1 303-271-7100 Toll Free: +1 855-929-7100 info@coorstek.com     From: *Info Sales Sent: Monday, September 26, 2016 9:14 AM To: 'frisch@hep.uchicago.edu' Subject: RE: Request for Information   Good Morning Henry,   Thank you for contacting CoorsTek.  We appreciate your inquiry.   I am checking to see if we are able to provide the information you are requesting.  Iÿÿll be in touch once I have some feedback.   Regards, Cheryl Connor Customer Engagement Center Lead cid:4FC8100E-53BC-416F-A3D3-8E0BF07A455E Phone: +1 303-271-7100 Toll Free: +1 855-929-7100 info@coorstek.com     From: webform@coorstek.com [mailto:webform@coorstek.com] Sent: Friday, September 23, 2016 8:02 AM To: *Info Sales Subject: Request for Information   FirstName - henry LastName - frisch Company - university of chicago JobTitle - Email - frisch@hep.uchicago.edu Comment - I'm using Coorstek AD-96 alumina at a frequency of 1 GHz-- would it be possible to get the values of the dielectric constant and loss tangent in this range? Thanks very much- Henry [ Part 2, "image001.png" Image/PNG 11KB. ] [ Unable to print this part. ]